"""Provides methods to configure the Txp measurement."""
import functools
import nirfmxlte.attributes as attributes
import nirfmxlte.enums as enums
import nirfmxlte.errors as errors
import nirfmxlte.internal._helper as _helper
def _raise_if_disposed(f):
"""From https://stackoverflow.com/questions/5929107/decorators-with-parameters."""
@functools.wraps(f)
def aux(*xs, **kws):
meas_obj = xs[0] # parameter 0 is 'self' which is the measurement object
if meas_obj._signal_obj.is_disposed:
raise Exception("Cannot access a disposed Lte signal configuration")
return f(*xs, **kws)
return aux
[docs]
class TxpConfiguration(object):
"""Provides methods to configure the Txp measurement."""
def __init__(self, signal_obj):
"""Provides methods to configure the Txp measurement."""
self._signal_obj = signal_obj
self._session_function_lock = signal_obj._session_function_lock
self._interpreter = signal_obj._interpreter
[docs]
@_raise_if_disposed
def get_measurement_enabled(self, selector_string):
r"""Gets whether to enable the Transmit Power (TXP) measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is FALSE.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (bool):
Specifies whether to enable the Transmit Power (TXP) measurement.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.TXP_MEASUREMENT_ENABLED.value
)
attr_val = bool(attr_val)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_measurement_enabled(self, selector_string, value):
r"""Sets whether to enable the Transmit Power (TXP) measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is FALSE.
Args:
selector_string (string):
Pass an empty string.
value (bool):
Specifies whether to enable the Transmit Power (TXP) measurement.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.TXP_MEASUREMENT_ENABLED.value,
int(value),
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_measurement_offset(self, selector_string):
r"""Gets the measurement offset to skip from the start of acquired waveform for TXP measurement. This value is
expressed in seconds.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the measurement offset to skip from the start of acquired waveform for TXP measurement. This value is
expressed in seconds.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_f64(
updated_selector_string, attributes.AttributeID.TXP_MEASUREMENT_OFFSET.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_measurement_offset(self, selector_string, value):
r"""Sets the measurement offset to skip from the start of acquired waveform for TXP measurement. This value is
expressed in seconds.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the measurement offset to skip from the start of acquired waveform for TXP measurement. This value is
expressed in seconds.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_f64(
updated_selector_string, attributes.AttributeID.TXP_MEASUREMENT_OFFSET.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_measurement_interval(self, selector_string):
r"""Gets the measurement interval. This value is expressed in seconds.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 1 ms.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the measurement interval. This value is expressed in seconds.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_f64(
updated_selector_string, attributes.AttributeID.TXP_MEASUREMENT_INTERVAL.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_measurement_interval(self, selector_string, value):
r"""Sets the measurement interval. This value is expressed in seconds.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 1 ms.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the measurement interval. This value is expressed in seconds.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_f64(
updated_selector_string,
attributes.AttributeID.TXP_MEASUREMENT_INTERVAL.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_averaging_enabled(self, selector_string):
r"""Gets whether to enable averaging for TXP measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **False**.
+--------------+-----------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+=================================================================================================================+
| False (0) | The number of acquisitions is 1. |
+--------------+-----------------------------------------------------------------------------------------------------------------+
| True (1) | The measurement uses the Averaging Count for the number of acquisitions over which the measurement is averaged. |
+--------------+-----------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.TxpAveragingEnabled):
Specifies whether to enable averaging for TXP measurement.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.TXP_AVERAGING_ENABLED.value
)
attr_val = enums.TxpAveragingEnabled(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_averaging_enabled(self, selector_string, value):
r"""Sets whether to enable averaging for TXP measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **False**.
+--------------+-----------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+=================================================================================================================+
| False (0) | The number of acquisitions is 1. |
+--------------+-----------------------------------------------------------------------------------------------------------------+
| True (1) | The measurement uses the Averaging Count for the number of acquisitions over which the measurement is averaged. |
+--------------+-----------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.TxpAveragingEnabled, int):
Specifies whether to enable averaging for TXP measurement.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
value = value.value if type(value) is enums.TxpAveragingEnabled else value
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.TXP_AVERAGING_ENABLED.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_averaging_count(self, selector_string):
r"""Gets the number of acquisitions used for averaging when
:py:attr:`~nirfmxlte.attributes.AttributeID.TXP_AVERAGING_ENABLED` is **True**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 10.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the number of acquisitions used for averaging when
:py:attr:`~nirfmxlte.attributes.AttributeID.TXP_AVERAGING_ENABLED` is **True**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.TXP_AVERAGING_COUNT.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_averaging_count(self, selector_string, value):
r"""Sets the number of acquisitions used for averaging when
:py:attr:`~nirfmxlte.attributes.AttributeID.TXP_AVERAGING_ENABLED` is **True**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 10.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the number of acquisitions used for averaging when
:py:attr:`~nirfmxlte.attributes.AttributeID.TXP_AVERAGING_ENABLED` is **True**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string, attributes.AttributeID.TXP_AVERAGING_COUNT.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_all_traces_enabled(self, selector_string):
r"""Enables the traces to be stored and retrieved after the TXP measurement is performed.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is False.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (bool):
Enables the traces to be stored and retrieved after the TXP measurement is performed.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.TXP_ALL_TRACES_ENABLED.value
)
attr_val = bool(attr_val)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_all_traces_enabled(self, selector_string, value):
r"""Enables the traces to be stored and retrieved after the TXP measurement is performed.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is False.
Args:
selector_string (string):
Pass an empty string.
value (bool):
Enables the traces to be stored and retrieved after the TXP measurement is performed.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.TXP_ALL_TRACES_ENABLED.value,
int(value),
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
@_raise_if_disposed
def get_number_of_analysis_threads(self, selector_string):
r"""Gets the maximum number of threads used for parallelism inside TXP measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The number of threads must range from 1 to the number of physical cores. The default value is 1.
The number of threads set used in calculations is not guaranteed. The actual number of threads used depends on
the problem size, system resources, data availability, and other considerations.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the maximum number of threads used for parallelism inside TXP measurement.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
attr_val, error_code = self._interpreter.get_attribute_i32(
updated_selector_string, attributes.AttributeID.TXP_NUMBER_OF_ANALYSIS_THREADS.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
[docs]
@_raise_if_disposed
def set_number_of_analysis_threads(self, selector_string, value):
r"""Sets the maximum number of threads used for parallelism inside TXP measurement.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The number of threads must range from 1 to the number of physical cores. The default value is 1.
The number of threads set used in calculations is not guaranteed. The actual number of threads used depends on
the problem size, system resources, data availability, and other considerations.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the maximum number of threads used for parallelism inside TXP measurement.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self._signal_obj
)
error_code = self._interpreter.set_attribute_i32(
updated_selector_string,
attributes.AttributeID.TXP_NUMBER_OF_ANALYSIS_THREADS.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code